The Cerabar S pressure transmitter measures the pressure of gases, steam/vapour and liquids and can be used in all areas of chemical and process engineering.

Operating principle 

Ceramic sensor

The system pressure acts directly on the rugged ceramic diaphragm of the pressure sensor deflecting it by a maximum of 0.025 mm. A pressure-proportional change in the capacitance is measured by the electrodes on the ceramic substrate and diaphragm.

The measuring range is determined by the thickness of the ceramic diaphragm.

Metal sensor

The process pressure deflects the separating diaphragm with a filling liquid transmitting the pressure to a resistance bridge. The bridge output voltage, which is proportional to pressure, is then measured and processed.

Level measurement

The hydrostatic pressure of a column of liquid enables its level to be measured continuously by a pressure transmitter if the densityρof the liquid is known.

CONTENTS:

1 Introduction ………… 9

1.1 Measuring system . . . . . . . . 10

2 Installation …………. 11

2.1 Mounting instructions without

diaphragm seal (PMC/PMP 731) . . 11

2.2 Mounting instructions with diaphragm

seal (PMC 631, PMP 635) . . . . . 13

2.3 Mounting accessories . . . . . . 14

2.4 Mounting position . . . . . . . . 15

2.5 Electrical connection . . . . . . . 16

3 Operation …………. 18

3.1 On-site operation . . . . . . . . 18

3.2 Operation using the Universal HART

Communicator DXR 271 . . . . . . 19

3.3 Operation with Commulog VU 260 Z . 19

3.4 Operation with Commuwin II . . . . 20

4 Local Operation ……….. 21

4.1 Commissioning the measuring point . 21

4.2 Dampingτ ……….. 23

4.3 Locking/unlocking operation . . . . 23

5 Pressure Measurement…….. 24

5.1 Start-up with the Universal HART

Communicator DXR 271,

Commulog VU 260 Z or Commuwin II 24

5.2 Locking/unlocking operation . . . . 28

5.3 Measuring point information . . . . 29

6 Level Measurement ……… 30

6.1 Start-up with the Universal HART

Communicator DXR 275,

Commulog VU 260 Z or Commuwin II 30

6.2 Calibration with reference pressure . 34

6.3 Dry calibration . . . . . . . . . 35

6.4 Linearisation . . . . . . . . . . 36

6.5 Locking/unlocking operation . . . . 39

6.6 Measuring point information . . . . 40

7 Diagnosis and Trouble-Shooting….41

7.1 Diagnosis of errors and warnings . . 41

7.2 Current simulation . . . . . . . . 44

7.3 Reset . . . . . . . . . . . . . 44

7.4 Editing limits . . . . . . . . . . 46

8 Maintenance and Repair …….48

8.1 Repair . . . . . . . . . . . . . 48

8.2 Mounting the display . . . . . . . 49

8.3 Exchanging the sensor module and

electronics . . . . . . . . . . . 50

8.4 Recalibration . . . . . . . . . . 51

8.5 Changing the gasket . . . . . . . 52

8.6 Replacement parts . . . . . . . . 52

9 Technical Data ………..54

10 Operating Matrix ……….59

10.1 Matrix HART Commuwin II

(Software version 7.1) . . . . . . . 59

10.2 Matrix Universal HART Communicator

DXR 275 (Software version 7.1) . . . 60

10.3 Block diagram . . . . . . . . . . 60

10.4 Matrix Commuwin II INTENSOR

(Software version 5.0) . . . . . . . 61

10.5 Description of parameters . . . . . 62

Index ……………67

LINK DOWNLOAD

How useful was this post?

Click on a star to rate it!

Average rating 0 / 5. Vote count: 0

No votes so far! Be the first to rate this post.

Updated: Tháng Mười Một 17, 2021 — 1:01 chiều
[ajax_load_more post_type="post, page"]

Trả lời

Email của bạn sẽ không được hiển thị công khai.

Tailieu4u.com - chia sẻ ebook- download free © 2017 Frontier Theme